8 research outputs found

    Surveillance of Airborne Adenovirus and Mycoplasma pneumoniae in a Hospital Pediatric Department

    Get PDF
    This investigation evaluated the distributions of airborne adenovirus and Mycoplasma pneumoniae in public areas in the pediatric department of Children's Hospital in northern Taiwan. The airborne viral and bacterial concentrations were evaluated twice a week for a year using filter sampling with an airflow rate of 12 liters per minute for eight hours in the pediatric outpatient department and 24 hours in the pediatric emergency room. Real-time polymerase chain reaction assays were conducted for analysis. Approximately 18% of the air samples from the pediatric emergency room were found to contain adenovirus. Approximately forty-six percent of the air samples from the pediatric outpatient department contained Mycoplasma pneumoniae DNA products. High detection rates of airborne adenovirus DNA were obtained in July and August in the pediatric public areas. Airborne Mycoplasma pneumoniae was detected only in July in the pediatric emergency room and the peak levels were found from August to January in the pediatric outpatient department. Airborne particles that contained adenovirus and Mycoplasma pneumoniae were the most prevalent in the pediatric public areas. The potential relationship between these airborne viral/bacterial particles and human infection should be examined further

    Association between respiratory tract diseases and secondhand smoke exposure among never smoking flight attendants: a cross-sectional survey

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Little is known about long-term adverse health consequences experienced by flight attendants exposed to secondhand smoke (SHS) during the time smoking was allowed on airplanes. We undertook this study to evaluate the association between accumulated flight time in smoky airplane cabins and respiratory tract diseases in a cohort of never smoking flight attendants.</p> <p>Methods</p> <p>We conducted a mailed survey in a cohort of flight attendants. Of 15,000 mailed questionnaires, 2053 (14%) were completed and returned. We excluded respondents with a personal history of smoking (n = 748) and non smokers with a history of respiratory tract diseases before the age of 18 years (n = 298). The remaining 1007 respondents form the study sample.</p> <p>Results</p> <p>The overall study sample was predominantly white (86%) and female (89%), with a mean age of 54 years. Overall, 69.7% of the respondents were diagnosed with at least one respiratory tract disease. Among these respondents, 43.4% reported a diagnosis of sinusitis, 40.3% allergies, 30.8% bronchitis, 23.2% middle ear infections, 13.6% asthma, 13.4% hay fever, 12.5% pneumonia, and 2.0% chronic obstructive pulmonary disease. More hours in a smoky cabin were observed to be significantly associated with sinusitis (OR = 1.21; p = 0.024), middle ear infections (OR = 1.30; p = 0.006), and asthma (OR = 1.26; p = 0.042).</p> <p>Conclusion</p> <p>We observed a significant association between hours of smoky cabin exposure and self-reported reported sinusitis, middle ear infections, and asthma. Our findings suggest a dose-response between duration of SHS exposure and diseases of the respiratory tract. Our findings add additional evidence to the growing body of knowledge supporting the need for widespread implementation of clean indoor air policies to decrease the risk of adverse health consequences experienced by never smokers exposed to SHS.</p

    Associations between respiratory illnesses and secondhand smoke exposure in flight attendants: A cross-sectional analysis of the Flight Attendant Medical Research Institute Survey

    Get PDF
    Abstract Background Secondhand tobacco smoke (SHS) is associated with increased risk of respiratory illness, cancer, and cardiovascular disease. Prior to smoking bans on airlines in the late 1980s, flight attendants were exposed to a significant amount of SHS. In the present study, we examine associations between flight attendant SHS exposure and development of respiratory illnesses and cardiovascular disease. Methods Between December 2006 and October 2010, three hundred sixty-two flight attendants completed an online questionnaire with information regarding experience as a flight attendant, medical history, smoking history, and SHS exposure. Rates of illnesses in flight attendants were compared with an age and smoking history matched population sample from NHANES 2005-2006. Logistic regression analysis was used to examine the association of reported medical conditions and pre-ban years of exposure. Results Compared with the sample from NHANES 2005-2006, flight attendants had increased prevalence of chronic bronchitis (11.7% vs. 7.2%, p &lt; 0.05), emphysema/COPD (3.2% vs. 0.9%, p &lt; 0.03), and sinus problems (31.5% vs. 20.9%, p &lt; 0.002), despite a lower prevalence of medical illnesses including high blood pressure, diabetes, high cholesterol, heart failure, cancer, and thyroid disease. Amongst flight attendants who reported never smoking over their lifetimes, there was not a significant association between years of service as a flight attendant in the pre-smoking ban era and illnesses. However, in this same group, there was a significantly increased risk of daily symptoms (vs. no symptoms) of nasal congestion, throat, or eye irritation per 10-year increase of years of service as a flight attendant prior to the smoking ban (OR 2.14, 95% CI 1.41 - 3.24). Conclusions Flight attendants experience increased rates of respiratory illnesses compared to a population sample. The frequency of symptoms of nasal congestion, throat or eye irritation is associated with occupational SHS exposure in the pre-smoking ban era

    Prenatal exposures and exposomics of asthma

    Get PDF
    This review examines the causal investigation of preclinical development of childhood asthma using exposomic tools. We examine the current state of knowledge regarding early-life exposure to non-biogenic indoor air pollution and the developmental modulation of the immune system. We examine how metabolomics technologies could aid not only in the biomarker identification of a particular asthma phenotype, but also the mechanisms underlying the immunopathologic process. Within such a framework, we propose alternate components of exposomic investigation of asthma in which, the exposome represents a reiterative investigative process of targeted biomarker identification, validation through computational systems biology and physical sampling of environmental medi

    Ventilation rates and health: multidisciplinary review of the scientific literature

    No full text
    The scientific literature through 2005 on the effects of ventilation rates on health in indoor environments has been reviewed by a multidisciplinary group. The group judged 27 papers published in peer-reviewed scientific journals as providing sufficient information on both ventilation rates and health effects to inform the relationship. Consistency was found across multiple investigations and different epidemiologic designs for different populations. Multiple health endpoints show similar relationships with ventilation rate. There is biological plausibility for an association of health outcomes with ventilation rates, although the literature does not provide clear evidence on particular agent(s) for the effects. Higher ventilation rates in offices, up to about 25 l/s per person, are associated with reduced prevalence of sick building syndrome (SBS) symptoms. The limited available data suggest that inflammation, respiratory infections, asthma symptoms and short-term sick leave increase with lower ventilation rates. Home ventilation rates above 0.5 air changes per hour (h(-1)) have been associated with a reduced risk of allergic manifestations among children in a Nordic climate. The need remains for more studies of the relationship between ventilation rates and health, especially in diverse climates, in locations with polluted outdoor air and in buildings other than offices. PRACTICAL IMPLICATIONS: Ventilation with outdoor air plays an important role influencing human exposures to indoor pollutants. This review and assessment indicates that increasing ventilation rates above currently adopted standards and guidelines should result in reduced prevalence of negative health outcomes. Building operators and designers should avoid low ventilation rates unless alternative effective measures, such as source control or air cleaning, are employed to limit indoor pollutant levels.link_to_subscribed_fulltex
    corecore